Round - Flat conductors
Under Construction
Hot dip galvanized steel (St/tZn) solid round conductor, with Zinc galvanizing coating weight of at least 350gr/m2. Used as air termination conductor, down conductor and as earth electr
Steel copper plated (St/Cu) solid round conductor. Used as air termination conductor, down conductor and as earth electrode.
Electrolytic copper (Cu-E) solid round conductor. Used as air termination conductor, down conductor and as earth electrode.
Copper tin plated (Cu/eSn) solid round conductor. Used as air termination conductor, down conductor and as earth electrode.
Aluminium alloy (AlMgSi) solid round conductor. Used as air termination conductor, down conductor and as earth electrode.
• Above ground
Stainless steel (INOX) solid round conductor. Used as air termination conductor, down conductor and as earth electrode.
• Durable in corrosive environment
Surface discharge-free and high voltage-resistant insulated arrestor to maintain the separation distance s ≤ 0,75 m.
Electrolytic copper (Cu-E) stranded conductor (annealed, soft drawn). Used in air interception-grounding conductor and down conductor.
Electrolytic copper tin plated (Cu/eSn) stranded conductor (annealed, soft drawn). Used in air interception-grounding conductor and down conductor.
Electrolytic copper PVC coated (Cu-E/PVC) stranded conductor (annealed, soft drawn). Used in air interception-grounding conductor and down conductor.
Hot dip galvanized steel (St/tZn) stranded conductor. Used in air interception-grounding conductor.
Stainless steel (INOX) stranded conductor. Used in air interception-grounding conductor.
Electrolytic copper (Cu-E) flexible stranded conductor. Used in grounding systems.
Copper tin plated (Cu/eSn) flexible stranded conductor. Used in grounding systems.
Electrolytic copper PVC coated (Cu-E/PVC) flexible stranded conductor. Used in grounding systems.
Preformed flexible stranded conductor with PVC insulation, used for equipotential bonding of metallic surfaces. The terminals are tin plated copper.
Straight round conductor hot dip galvanized steel (St/tZn) diameter Ø 16 mm used for lightning protection - earthing.
Straight round conductor electrolytic copper (Cu-E) diameter Ø 16 mm used for lightning protection - earthing.
Earth lead-in rod single point hot dip galvanized steel (St/tZn) diameter Ø 16 mm, which connect the lightning protection system down conductors and the earthing system, so as to protect th
Earth lead-in rod double point hot dip galvanized steel (St/tZn) diameter Ø 16 mm, which connect the lightning protection system down conductors and the earthing system, so as to protect th
Earth lead-in rod single point electrolytic copper (Cu-E) diameter Ø 16 mm, which connect the lightning protection system down conductors and the earthing system, so as to protect the down
Earth lead-in rod double point electrolytic copper (Cu-E) diameter Ø 16 mm, which connect the lightning protection system down conductors and the earthing system, so as to protect the down
Tape conductor (strip) hot dip galvanized steel (St/tZn) used in earthing systems. They are also used in lightning protection systems for equipotential bonding.
Tape conductor (strip) steel copper plated (St/Cu) used in earthing systems. They are also used in lightning protection systems for equipotential bonding.
Tape conductor (strip) electrolytic copper (Cu-E) used in earthing systems. They are also used in lightning protection systems for equipotential bonding.
Tape conductor (strip) copper tin plated (Cu/eSn) used in earthing systems. They are also used in lightning protection systems for equipotential bonding.
Tape conductor (strip) stainless steel (INOX) used in earthing systems. They are also used in lightning protection systems for equipotential bonding.
Flexible stranded tape conductor electrolytic copper (Cu-E) constructed by strands with diameter 0.2mm used for equipotential bonding of metallic surfaces.
Flexible stranded tape conductor copper tin plated (Cu/eSn) constructed by strands with diameter 0.2mm used for equipotential bonding of metallic surfaces.
Preformed flexible stranded tape conductor electrolytic copper (Cu-E), in length 300 - 500 mm used for equipotential bonding of metallic surfaces. The terminals are tin plated copper.
Preformed flexible stranded conductor copper tin plated (Cu/eSn), in length 300 - 500 mm used for equipotential bonding of metallic surfaces. The terminals are tin plated copper.
Contraction-expansion absorbing conductor hot dip galvanized steel (St/tZn) which is installed at intervals of approximately 20 meters of straight or crossing air termination system conductors &Os
Contraction-expansion absorbing conductor electrolytic copper (Cu-E) which is installed at intervals of approximately 20 meters of straight or crossing air termination system conductors Ø 8
Contraction-expansion absorbing conductor copper tin plated (Cu/eSn) which is installed at intervals of approximately 20 meters of straight or crossing air termination system conductors Ø 8
Contraction-expansion absorbing conductor aluminium alloy (AlMgSi) which is installed at intervals of approximately 20 meters of straight or crossing air termination system conductors Ø 8-1
Contraction-expansion absorbing conductor cross hot dip galvanized steel (St/tZn) which is installed at intervals of approximately 20 meters of straight or crossing air termination system conducto
Contraction-expansion absorbing conductor cross electrolytic copper (Cu-E) which is installed at intervals of approximately 20 meters of straight or crossing air termination system conductors &Osl
Contraction-expansion absorbing conductor cross aluminium alloy (AlMgSi) which is installed at intervals of approximately 20 meters of straight or crossing air termination system conductors &Oslas